Is 4 channel DWDM MUX DEMUX Dual Fiber type meet your data center's requirement?

The 4 channel DWDM passive MUX and DEMUX modules deliver the benefits of a Dense Wave Division Multiplexer in a fully passive solution. With matching MUX and DEMUX units placed at each end of an optical link, up to 4 data channels can be combined and transmitted over a single-mode fiber trunk.

4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount

The HT6000-ODM04 is ideal for increasing the fiber capacity between two sites without the need for installing or leasing additional fibers.

The HT6000-ODM04 may be used as a standalone tabletop device or mounted in 1-unit space of a 19” data rack It can achieve bi-directional 4CH data multiplex and demultiplex.

The complete passive solution requires no power cabling and no configuration; it is a true plug and play solution.

Features
(1) 4 Channels 100 GHz DWDM combined Multiplexer and Demultiplexer (MUX & DEMUX)
(2) Standalone compact form factor-1U, Installation friendly
(3) Plug’n play: requires no configuration
(4) Green product: completely passive, needs no power and no cooling
(5) Low insertion loss, insertion loss ≤1.8dB, 
(6) High channel isolation:adjacent isolation ≥25dB; non-adjacent isolation ≥40dB
(7) Compatible with 100GHz ITU Grid DWDM active transponders and transceivers from Htfuture and other third parties
(8) High reliability, MTBF of 100 years
(9) Designed for Telcordia / Bellcore GR-120

Applications
(1) DWDM transmission 
(2) Metro and long-haul networks 
(3) Point-to-point DWDM fiber optimization
(4) Linear add/drop DWDM fiber optimization
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount

Specifications

Parameter
4 Channel
8 Channel
16 Channel
MUX
DEMUX
MUX
DEMUX
MUX
DEMUX
Channel Wavelength (nm)
ITU 100GHz Grid
Center wavelength Accuracy (nm)
±0.1
Channel Spacing (nm)
0.8nm (100GHz)
Channel Passband (@-0.5dB bandwidth (nm)
>0.25
Insertion Loss (dB)
≤1.8
≤3.0
4
Channel Uniformity (dB)
≤0.6
≤1.0
≤1.5
Channel Ripple (dB)
0.3
Isolation (dB)
Adjacent
N/A
>30
N/A
>30
N/A
>30
Non-adjacent
N/A
>40
N/A
>40
N/A
>40
Inertion Loss Temperature Sensitivity (dB/℃)
<0.005
Wavelength Temperature Shifting (nm/℃)
<0.002
Polarization Dependent Loss (dB)
<0.1
<0.1
<0.15
Polarization Mode Dispersion
<0.1
Directivity (dB)
>50
Return Loss (dB)
>45
Maximum Power Handling (mW)
300

Company Information
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount 

Product Range
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount


Certifications
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount 
FAQ
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount 
Contact HTFuture
4CH DWDM MUX DEMUX Dual Fiber 1U Rack Mount


Ivy Huang is sales engineer at HTFuture. More information on HTFuture’s Mux Demux product is available by emailing sales6@htfuture.com or visiting www.htfuture.com.

Related Product:

DWDM/CWDM 4/8/16/18ch/Customized channel MUX DEMUX, Passive CCWDM 4/8/16/18ch MUX-DEMUX, AWG 40/48ch MUX DEMUX, Dual/Single fiber is available) 

Due the low insertion loss is needed in WDM networks, we can also add “Skip Component” in a CWDM Mux/Demux module to reduce the IL as an option. Standard CWDM Mux/Demux package type include: ABS box package, LGX package and 19" 1U rack mount.

没有评论:

发表评论

Single Fiber Qsfp28 80km Lc Optical Module

  Now only one fiber can transmit 100G under distance 80km. 100G BIDI 80km. why use this optical module? (1) save one fiber rent. (2) easy t...